BoneCom® Low-loss, high-strength single-mode fiber SL-G.652.D
Product Performance
Ultra-low transmission loss, @1550nm≤ 0.180dB/km, @1310nm≤ 0.320dB/km.
Optimized PMD characteristics, low splice loss and excellent compatibility.
Optional high screening strength to suit submarine cable requirements.
Application Scenarios
100G and B100G high-speed long-distance transmission systems.
High-capacity ocean communication networks and submarine observation networks.
Broadband metropolitan area network.
Product Specification
Characteristics |
Conditions |
Units |
Specified values |
Optical Characteristics |
|||
Attenuation |
1310nm |
dB/km |
≤ 0.320 |
1383nm |
dB/km |
≤ 0.320 |
|
1550nm |
dB/km |
≤ 0.180 |
|
1625nm |
dB/km |
≤ 0.220 |
|
Relative wavelength attenuation changes |
1310nm VS. 1285-1330mn |
dB/km |
≤ 0.04 |
1550nm VS. 1525-1575mn |
dB/km |
≤ 0.03 |
|
Zero Dispersion Wavelength(λ0) |
- |
nm |
1300-1324 |
Zero Dispersion Slope |
- |
ps/nm2·km |
0.073-0.092 |
Dispersion |
1550nm |
ps/nm·km |
13.3-18.6 |
1625nm |
ps/nm·km |
17.2-23.7 |
|
PMD |
- |
ps/√km |
≤ 0.08 |
Cable Cutoff Wavelength(λcc) |
- |
nm |
≤ 1260 |
Mode Field Diameter (MFD) |
1310nm |
μm |
9.2±0.4 |
1550mn |
μm |
10.4±0.5 |
|
Attenuation discontinuity |
1310nm |
dB |
≤ 0.03 |
1550mn |
dB |
≤ 0.03 |
|
Attenuation of the two-way end difference |
1310nm |
dB/km |
≤ 0.03 |
1550nm |
dB/km |
≤ 0.03 |
|
Geometrical Characteristics |
|||
Cladding Diameter |
μm |
125±0.7 |
|
Cladding Non-Circularity |
% |
≤ 1.0 |
|
Core-Cladding Concentricity Error |
μm |
≤ 0.6 |
|
Coating Diameter |
μm |
242±7 |
|
Coating-Cladding Concentricity Error |
μm |
≤ 12 |
|
Curl (Radius) |
m |
≥ 4 |
|
Environmental Characteristics 1550nm &1625nm |
|||
Temperature Dependence Induced Attenuation |
-60℃ to +85℃ |
dB/km |
≤ 0.03 |
Damp Heat Dependence Induced Attenuation |
85℃ and 85% RH, for 30 days |
dB/km |
≤ 0.03 |
Watersoak Dependence Induced Attenuation |
23℃, for 30 days |
dB/km |
≤ 0.03 |
Dry Heat Induced Attenuation |
85℃, for 30 days |
dB/km |
≤ 0.03 |
Mechanical properties |
|||
Tension screening * |
- |
GPa |
0.69 |
- |
kpsi |
100 |
|
Coating Strip Force |
peak force |
N |
1.3-8.9 |
typical average force |
N |
1.0-5.0 |
|
Tensile Strength |
Weber Probability 50% |
GPa |
≥ 4.00 |
Weber Probability 15% |
GPa |
≥ 3.20 |
|
Dynamic Fatigue Parameter(nd) |
- |
- |
≥ 20 |
Macro-bend Induced Attenuation |
|||
Ø60mm×100 |
1550nm |
dB |
≤ 0.05 |
1625nm |
dB |
≤ 0.05 |
|
*Higher screening tension products are available. |
Partner





Hot Tags: sl-g.652.d, China sl-g.652.d manufacturers, suppliers, building vertical runs optical cables, optical cable for indoor use, interior optical cable for lan, optical cable marking for indoor, optical fibre patch cable for indoor, indoor fiber optic cable testing