SL-G.652.D

SL-G.652.D
Details:
BoneCom® SL-G.652.D dramatically improves its intensity and attenuation performance through advanced fabrication techniques, with low loss characteristics in a wide wavelength band, especially at 1550nm wavelengths. It has a wide range of applications, especially for long-distance trunk lines, marine communications, and submarine observation networks.
Send Inquiry
Download
Description
Technical Parameters
BoneCom® Low-loss, high-strength single-mode fiber SL-G.652.D

 

 

Product Performance

1

Ultra-low transmission loss, @1550nm≤ 0.180dB/km, @1310nm≤ 0.320dB/km.

2

Optimized PMD characteristics, low splice loss and excellent compatibility.

3

Optional high screening strength to suit submarine cable requirements.

 

Application Scenarios

1

100G and B100G high-speed long-distance transmission systems.

2

High-capacity ocean communication networks and submarine observation networks.

3

Broadband metropolitan area network.

 

Product Specification
 

 

Characteristics

Conditions

Units

Specified values

Optical Characteristics

Attenuation

1310nm

dB/km

≤ 0.320

1383nm

dB/km

≤ 0.320

1550nm

dB/km

≤ 0.180

1625nm

dB/km

≤ 0.220

Relative wavelength attenuation changes

1310nm VS. 1285-1330mn

dB/km

≤ 0.04

1550nm VS. 1525-1575mn

dB/km

≤ 0.03

Zero Dispersion Wavelength(λ0)

-

nm

1300-1324

Zero Dispersion Slope

-

ps/nm2·km

0.073-0.092

Dispersion

1550nm

ps/nm·km

13.3-18.6

1625nm

ps/nm·km

17.2-23.7

PMD

-

ps/√km

≤ 0.08

Cable Cutoff Wavelength(λcc)

-

nm

≤ 1260

Mode Field Diameter (MFD)

1310nm

μm

9.2±0.4

1550mn

μm

10.4±0.5

Attenuation discontinuity

1310nm

dB

≤ 0.03

1550mn

dB

≤ 0.03

Attenuation of the two-way end difference

1310nm

dB/km

≤ 0.03

1550nm

dB/km

≤ 0.03

Geometrical Characteristics

Cladding Diameter

μm

125±0.7

Cladding Non-Circularity

%

≤ 1.0

Core-Cladding Concentricity Error

μm

≤ 0.6

Coating Diameter

μm

242±7

Coating-Cladding Concentricity Error

μm

≤ 12

Curl (Radius)

m

≥ 4

Environmental Characteristics 1550nm &1625nm

Temperature Dependence Induced Attenuation

-60℃ to +85℃

dB/km

≤ 0.03

Damp Heat Dependence Induced Attenuation

85℃ and 85% RH, for 30 days

dB/km

≤ 0.03

Watersoak Dependence Induced Attenuation

23℃, for 30 days

dB/km

≤ 0.03

Dry Heat Induced Attenuation

85℃, for 30 days

dB/km

≤ 0.03

Mechanical properties

Tension screening *

-

GPa

0.69

-

kpsi

100

Coating Strip Force

peak force

N

1.3-8.9

typical average force

N

1.0-5.0

Tensile Strength

Weber Probability 50%

GPa

≥ 4.00

Weber Probability 15%

GPa

≥ 3.20

Dynamic Fatigue Parameter(nd)

-

-

≥ 20

Macro-bend Induced Attenuation

Ø60mm×100

1550nm

dB

≤ 0.05

1625nm

dB

≤ 0.05

*Higher screening tension products are available.

 

 