BendCom® Bend-resistant single-mode fiber G.657.A1
Product Performance
Low-loss performance and bend-insensitive performance.
The fibers are available in two available diameters: 245μm(standard)/200μm(optional).
Optimized MFD and precise geometrical properties.
Good compatibility with G.652.D single-mode fiber.
Application Scenarios
Gigabit broadband home and FTTP, etc.
Pre-5G network construction, etc.
Data center, computer interconnection.
Product Specification
|
Characteristics |
Conditions |
Units |
Specified values |
|
Optical Characteristics |
|||
|
Attenuation |
1310nm |
dB/km |
≤ 0.350 |
|
1383nm |
dB/km |
≤ 0.350 |
|
|
1550nm |
dB/km |
≤ 0.210 |
|
|
1625nm |
dB/km |
≤ 0.230 |
|
|
Relative Wavelength Attenuation Changes |
1310nm VS. 1285-1330mn |
dB/km |
≤ 0.04 |
|
1550nm VS. 1525-1575mn |
dB/km |
≤ 0.03 |
|
|
Zero Dispersion Wavelength(λ0) |
- |
nm |
1300-1324 |
|
Zero Dispersion Slope |
- |
ps/nm2·km |
≤ 0.092 |
|
PMD |
- |
ps/√km |
≤ 0.2 |
|
Cable Cutoff Wavelength(λcc) |
- |
nm |
≤ 1260 |
|
Mode Field Diameter (MFD) |
1310nm |
μm |
9.2±0.4 |
|
1550mn |
μm |
10.4±0.5 |
|
|
Attenuation discontinuity |
1310nm |
dB |
≤ 0.03 |
|
1550mn |
dB |
≤ 0.05 |
|
|
Geometrical Characteristics |
|||
|
Cladding Diameter |
μm |
125±0.7 |
|
|
Cladding Non-Circularity |
% |
≤ 1.0 |
|
|
Core-Cladding Concentricity Error |
μm |
≤ 0.5 |
|
|
Coating Diameter |
μm |
242±7 |
|
|
200±10 |
|||
|
Coating-Cladding Concentricity Error |
μm |
≤ 12 |
|
|
Curl (Radius) |
m |
≥ 4 |
|
|
Environmental Characteristics 1550nm &1625nm |
|||
|
Temperature Dependence Induced Attenuation |
-60℃ to +85℃ |
dB/km |
≤ 0.05 |
|
Damp Heat Dependence Induced Attenuation |
85℃ and 85% RH, for 30 days |
dB/km |
≤ 0.05 |
|
Watersoak Dependence Induced Attenuation |
23℃, for 30 days |
dB/km |
≤ 0.05 |
|
Dry Heat Induced Attenuation |
85℃, for 30 days |
dB/km |
≤ 0.05 |
|
Mechanical properties |
|||
|
Tension screening |
- |
GPa |
0.69 |
|
- |
kpsi |
100 |
|
|
Coating Strip Force * |
peak force |
N |
1.3-8.9 |
|
typical average force |
N |
1.0-5.0 |
|
|
Tensile Strength |
Weber Probability 50% |
GPa |
≥ 4.00 |
|
Weber Probability 15% |
GPa |
≥ 3.20 |
|
|
Dynamic Fatigue Parameter(nd) |
- |
- |
≥ 20 |
|
Macro-bend Induced Attenuation |
|||
|
Ø30mm×10 |
1550nm |
dB |
≤ 0.25 |
|
1625nm |
dB |
≤ 1.0 |
|
|
Ø20mm×1 |
1550nm |
dB |
≤ 0.75 |
|
1625nm |
dB |
≤ 1.5 |
|
|
*At a coating diameter of 200±10, the coating peel force peaks at 0.6-8.9 N and averages 0.6-5.0 N |
|||
Partner





Hot Tags: g.657.a1, China g.657.a1 manufacturers, suppliers, optical cables for vertical cable signaling in buildings, interior optical cable splice, interior optical fibre cable hanger, building vertical cable connectivity fiber optic cables, interior optical fibre cable testing, optical cables for vertical cable data transfer in buildings