G.652.D

G.652.D
Details:
Conventional single-mode fiber, also known as non-dispersion shift single-mode fiber with wavelength band extension, is the most widely used optical fiber with a working wavelength of 1310nm or 1550nm.
Send Inquiry
Download
Description
Technical Parameters
BoneCom® Conventional single-mode fiber G.652.D

 

 

Product Performance

1

Wider wavelength range for high-speed networks.

2

Accurate Mold Field Diameter (MFD) characteristics ensure low splice losses and good compatibility.

 

Application Scenarios

1

100G and B100G high-speed long-haul long-span backbones.

2

High-bandwidth metro networks and access networks.

 

Product Specification
 

 

Characteristics

Conditions

Units

Specified values

Optical Characteristics

Attenuation

1310nm

dB/km

≤ 0.350

1383nm

dB/km

≤ 0.340

1550nm

dB/km

≤ 0.210

1625nm

dB/km

≤ 0.240

Relative wavelength attenuation changes

1310nm VS. 1285-1330mn

dB/km

≤ 0.04

1550nm VS. 1525-1575mn

dB/km

≤ 0.03

Zero Dispersion Wavelength(λ0)

-

nm

1300-1324

Zero Dispersion Slope

-

ps/nm2·km

0.073-0.092

Dispersion

1550nm

ps/nm·km

13.3-18.6

1625nm

ps/nm·km

17.2-23.7

PMD

-

ps/√km

≤ 0.15

Cable Cutoff Wavelength(λcc)

-

nm

≤ 1260

Mode Field Diameter (MFD)

1310nm

μm

9.2±0.4

1550mn

μm

10.4±0.5

Attenuation Discontinuity

1310nm

dB

≤ 0.03

1550mn

dB

≤ 0.05

Attenuation of the two-way end difference

1310nm

dB/km

≤ 0.04

1550nm

dB/km

≤ 0.04

Geometrical Characteristics

Cladding Diameter

μm

125±0.7

Cladding Non-Circularity

%

≤ 1.0

Core-Cladding Concentricity Error

μm

≤ 0.6

Coating Diameter

μm

242±7

200±10

Coating-Cladding Concentricity Error

μm

≤ 12

Curl (Radius)

m

≥ 4

Environmental Characteristics 1550nm &1625nm

Temperature Dependence Induced Attenuation

-60℃ to +85℃

dB/km

≤ 0.03

Damp Heat Dependence Induced Attenuation

85℃ and 85% RH, for 30 days

dB/km

≤ 0.03

Watersoak Dependence Induced Attenuation

23℃, for 30 days

dB/km

≤ 0.03

Dry Heat Induced Attenuation

85℃, for 30 days

dB/km

≤ 0.03

Mechanical properties

Tension screening *

-

GPa

0.69

-

kpsi

100

Coating Strip Force

peak force

N

1.3-8.9

typical average force

N

1.0-5.0

Tensile Strength

Weber Probability 50%

GPa

≥ 4.00

Weber Probability 15%

GPa

≥ 3.20

Dynamic Fatigue Parameter(nd)

-

-

≥ 20

Macro-bend Induced Attenuation

Ø60mm×100

1550nm

dB

≤ 0.05

1625nm

dB

≤ 0.05

Ø20mm×1

1550nm

dB

≤ 0.05

1625nm

dB

≤ 0.05

*Higher screening tension products are available.

 

 

Partner
 

 

QQ20240313133734
product-879-333
168429940411
product-1010-435
product-884-351

 

Hot Tags: g.652.d, China g.652.d manufacturers, suppliers, fiber optic cable for indoor systems, building vertical cable expansion fiber optic cables, optical cable for indoor communication, indoor optical fibre link cable, building vertical cable retrofit fiber optic cables, optical cables for vertical cable management in buildings