LL-G.652.D

LL-G.652.D
Details:
BoneCom® Low-loss single-mode fiber LL-G.652.D has the excellent characteristics of wide band and low loss, and the wavelengths of 1550nm, 1310nm and 1383nm all have excellent attenuation characteristics, which are suitable for 100G high-speed optical fiber communication systems, which can extend the span, reduce amplifier investment, reduce the cost of operator network construction, and meet the needs of "increasing network speed and reducing network fees".
Send Inquiry
Download
Description
Technical Parameters
BoneCom® Low-loss single-mode fiber LL-G.652.D

 

 

Product Performance

1

Wavelength attenuation coefficients: 1550nm≤ 0.185 dB/km, 1310nm≤0.330 dB/km

2

Accurate Mold Field Diameter (MFD) characteristics ensure low splice losses and good compatibility.

 

Application Scenarios

1

100G and B100G high-speed long-haul long-span backbones.

2

400G ultra-high-speed network construction.

3

High-bandwidth metro network.

 

Product Specification
 

 

Characteristics

Conditions

Units

Specified values

Optical Characteristics

Attenuation

1310nm

dB/km

≤ 0.330

1383nm

dB/km

≤ 0.330

1550nm

dB/km

≤ 0.185

1625nm

dB/km

≤ 0.220

Relative wavelength attenuation changes

1310nm VS. 1285-1330mn

dB/km

≤ 0.04

1550nm VS. 1525-1575mn

dB/km

≤ 0.03

Zero Dispersion Wavelength(λ0)

-

nm

1300-1324

Zero Dispersion Slope

-

ps/nm2·km

0.073-0.092

Dispersion

1550nm

ps/nm·km

13.3-18.6

1625nm

ps/nm·km

17.2-23.7

PMD

-

ps/√km

≤ 0.1

Cable Cutoff Wavelength(λcc)

-

nm

≤ 1260

Mode Field Diameter (MFD)

1310nm

μm

9.2±0.4

1550mn

μm

10.4±0.5

Attenuation discontinuity

1310nm

dB

≤ 0.03

1550mn

dB

≤ 0.03

Attenuation of the two-way end difference

1310nm

dB/km

≤ 0.03

1550nm

dB/km

≤ 0.03

Geometrical Characteristics

Cladding Diameter

μm

125±0.7

Cladding Non-Circularity

%

≤ 1.0

Core-Cladding Concentricity Error

μm

≤ 0.6

Coating Diameter

μm

242±7

200±10

Coating-Cladding Concentricity Error

μm

≤ 12

Curl (Radius)

m

≥ 4

Environmental Characteristics 1550nm &1625nm

Temperature Dependence Induced Attenuation

-60℃ to +85℃

dB/km

≤ 0.03

Damp Heat Dependence Induced Attenuation

85℃ and 85% RH, for 30 days

dB/km

≤ 0.03

Watersoak Dependence Induced Attenuation

23℃, for 30 days

dB/km

≤ 0.03

Dry Heat Induced Attenuation

85℃, for 30 days

dB/km

≤ 0.03

Mechanical properties

Tension Screening *

-

GPa

0.69

-

kpsi

100

Coating Strip Force **

peak force

N

1.3-8.9

typical average force

N

1.0-5.0

Tensile Strength

Weber Probability 50%

GPa

≥ 4.00

Weber Probability 15%

GPa

≥ 3.20

Dynamic Fatigue Parameter(nd)

-

-

≥ 20

Macro-bend Induced Attenuation

Ø60mm×100

1550nm

dB

≤ 0.05

1625nm

dB

≤ 0.05

*Higher screening tension products are available.

**At a coating diameter of 200±10, the coating peel force peaks at 0.6-8.9 N and averages 0.6-5.0N.

 

 

Partner
 

 

QQ20240313133734
product-879-333
168429940411
product-1010-435
product-884-351

 

Hot Tags: ll-g.652.d, China ll-g.652.d manufacturers, suppliers, building vertical networking fiber optic cables, optical cables for vertical cable integration in buildings, optical cables for vertical trunking in buildings, vertical wiring optical cables in buildings, optical fibre patch cable for indoor, optical cables for vertical cable connectivity in buildings