Jul 11, 2024

SELECTION AND QUALIFICATION OF REFERENCE COMPONENTS

Leave a message

A. Single-Mode

The values in Table A1 are recommended for the following Class IA multi-mode fiber types installed in non-angled physical contact connectors:

50/125 graded index, 0.2 NA

62.5/125 graded index, 0.275 NA

Table A-Recommended Multi-mode Reference Connector Criteria

Parameter

Reference Criteria

Ferrule outside diameter

2.4990±0.0005mm

Connector endface geometry:

Radius of curvature

Apex offset

Fiber height

10 to 25 mm

50 microns maximum

± 50 nm

Polished ferrule length

Per applicable FOCIS document requirement

Reference connector loss

≤0.25dB at 850 and 1300nm

Beam exit angle

≤0.5 degree

Fiber core position

Eccentricity ≤ 3 microns

 

B. Single-Mode

The values in table A2 are recommended for the following Class IV single-mode fiber

types installed in non-angled physical contact connectors:

9.3/125, 1310/1550nm, 0.13 NA

Table B – Recommended Single-Mode Reference Connector Criteria

Parameter

Reference Criteria

Ferrule outside diameter

2.4990±0.0005mm

Connector endface geometry:

Radius of curvature

Apex offset

Fiber height

10 to 25 mm

50 microns maximum

± 50 nm

Polished ferrule length

Per applicable FOCIS document requirement

Reference connector loss

≤0.15dB at 1310 and 1550nm

Beam exit angle

≤0.25 degree

Fiber core position

Eccentricity ≤ 0.25 microns

 