Research on Level 1 Combustion Performance of GYTAH58 Optical Cable

Leave a message

As an important medium for information transmission, the flame retardant performance of optical cables has attracted much attention. In a closed fire environment, due to the consumption of a large amount of oxygen and the release of a large amount of heat and dust during combustion, it poses a significant threat to personnel evacuation and equipment safety. In August 2020, the national standard GB51348-2019 (<Electrical Design Standard for Civil Buildings') explicitly required the use of B-grade communication optical cable products in civil buildings. In June 2023, the national standard GB55037-2022 (<General Code for Building Fire Protection ') explicitly required the use of Bl grade data communication cable products in subway engineering. The B1 grade combustion performance not only requires flame retardancy, but also has an impact on heat release rate

 

Detailed specifications have been made for peak value, total heat release, combustion droplets, smoke toxicity, and corrosiveness. Ordinary flame-retardant optical cables are difficult to meet the requirements, so it is necessary to study and develop the Bl level combustion performance of optical cables.

 

This article only discusses the combustion performance of Bl grade, without elaborating on additional grades such as&P combustion droplets, smoke toxicity, and corrosiveness. The combustion performance, test methods, and grading criteria for B1 grade optical cables are clearly required by national standards, including GBrr 31247-2014<<Classification of Combustion Performance of Cables and Optical Cables GBff 31248-2014<<Test Methods for Flame Spread, Heat Release, and Smoke Production Characteristics of Cables or Optical Cables under Fire Conditions', GBff 17651.2-2021<<Determination of Smoke Density of Cables or Optical Cables Burning under Specific Conditions Part 2: Test Procedures and Requirements', and GB Hall 23818380.12-2022<<<Combustion Test of Cables and Optical Cables under Fire Conditions Part 12: Vertical Flame Spread Test of Single Insulated Wire and Cable, LKW Pre Tear Fusion Flame Test Method). Straight flame vine extension for the people | The flame is called "Gan" and is called "Da Yi" in 2022, with a carbonization distance of 425mm

 

According to the preliminary experimental data statistics, the binding method, flame shape, and nozzle aperture are all factors affecting the peak heat release rate and total heat release performance. To ensure data consistency, 3.1 GYTAH58 fiber optic cable structure design and test plan. In the flame-retardant fiber optic cable structure, a large amount of fiber paste and cable paste inside the cable

 

Waiting for combustibles can lead to peak heat release rate (HRR), total heat release (THR) within 1200 seconds of exposure to fire, and total smoke production (TSP) within 1200 seconds of exposure to fire. In this paper, while minimizing the internal combustibles of the optical cable, the optimal structure is adopted to develop high shell materials for the inner protective layer and ultra-high flame retardant materials for the outer protective layer that absorb heat and resist dripping. The structural dimensions of GYTAH58 optical cable are kept consistent, and the inner and outer sheaths are made of ceramic oxygen barrier material (TC), hydrogen peroxide mirror (MH), and aluminum hydroxide (Ø í. IV), as well as low smoke halogen-free sheath materials mainly composed of the latter two in different proportions. The following six test schemes show the most obvious expansion, while the inner protective aluminum tape expands. The outer protective layer transfers heat to the internal cable core during combustion. If the inner and outer protective layers cannot form a shell to isolate most of the external heat, the accumulated heat inside the cable core will expand, causing the inner aluminum strip and outer steel strip of the optical cable to expand, resulting in uncontrolled combustion. MH flame retardants have good thermal stability, non toxicity, smoke suppression, and efficient promotion of substrate carbonization. They also have the function of neutralizing acidic and corrosive gases generated during combustion without producing corrosive gases. The decomposition energy of MH flame retardants is 1244J/g, which is higher than the decomposition energy of 1127J/g. Therefore, using MH flame retardant fuel for both the inner and outer sheaths helps to improve the efficiency of flame retardancy.

 

In the structural design of GYTAH58 optical cable, three different low smoke halogen-free sheathing materials were used for the combination of inner and outer sheathing, and six schemes of Bl level flame-retardant optical cable sheathing materials were designed. Through experimental comparison, it was found that both the inner and outer sheathing used aluminum hydroxide flame retardant fuel, and both the inner and outer sheathing used hydrogen oxide mirror and aluminum hydroxide compound flame retardant fuel schemes, which did not meet the requirements of Bl level flame-retardant performance. The inner sheathing used ceramic oxygen barrier material, and the outer sheathing used hydrogen oxide mirror and aluminum hydroxide compound flame retardant fuel, which could meet the requirements of Bl level combustion performance indicators: both the inner and outer sheathing used MH flame retardant fuel, and B1 level combustion performance was the most excellent. However, the use of high filling hydrogen oxide mirror sheathing material did not meet the requirements of Bl level flame-retardant performance. The mechanical properties and crack resistance of flame-retardant optical cables are relatively poor. In addition, there is a certain correlation between the carbonization height of optical cable combustion and the peak heat release rate and total heat release. As the carbonization height increases, the peak heat release rate and total heat release show an upward trend.