OTDR curve analysis is an important part of fiber optic testing. By analyzing the OTDR curve, the quality and performance of the fiber can be understood. The following is a detailed explanation of the basic concepts, common abnormal curves, their causes, and countermeasures of OTDR curves:
The basic concept of OTDR curve:
OTDR (Optical Time Domain Reflectometer) plots a curve by sending optical pulses to an optical fiber and measuring the reflected optical signal. Each point on the curve represents the optical signal intensity of the fiber at different positions. By analyzing these curves, issues such as fiber loss, breakage, and connection quality can be detected.
Common abnormal curves and their causes and countermeasures
No Fresnel reflection peak at the end of the optical fiber:
Reason: The fiber end surface is dirty or of poor quality.
Countermeasure: Clean the fiber end face or redo the end face.
The curve is clearly arched, with severe attenuation that is either too large or too small
Reason: Range setting error (less than twice the length of the measured fiber).
Countermeasure: Increase the range.
There is a 'small mountain peak' in the middle of the curve:
Reason: Due to the quality of the fiber itself (small cracks) or the reflection of secondary reflection residual waves at the front end face.
Countermeasure: Change the fiber testing range and pulse width, redo the end face, and retest. If the 'small mountain peak' disappears, it is a secondary reflection residual wave; If it doesn't disappear, it's a quality issue with the fiber itself.
Significant gain is generated at fiber optic connectors, couplers, and fusion points:
Reason: Mismatch of mode field diameter.
Countermeasure: Conduct bidirectional testing for attenuation and joint loss, and take the average value.
The slope of the curve is normal, but the attenuation coefficients of the two ends of the fiber are significantly different:
Reason: Uneven mode field, usually in the fiber drawing head and tail section.
Countermeasure: Conduct bidirectional testing for attenuation and take the average value.
The attenuation of the entire fiber is qualified, but there is a small depression at the front of the Fresnel reflection peak:
Reason: The fiber optic cable at the end of several meters or tens of meters is subjected to lateral pressure.
Countermeasure: Repeat the observation to see if there are any changes.
The curve of 1310nm fiber is smooth, but the attenuation slope of 1550nm fiber increases:
Reason: The excess length inside the bundle tube is too short, causing the optical fiber to be stretched.
Countermeasure: Confirm the remaining length inside the bundle tube and increase the remaining length inside the bundle tube.