MultiCom® Bending Insensitive 50/125 Multimode Optical Fiber (OM5)
Product Performance
Precise refractive index distribution
Outstanding bending resistance.
Low attenuation and high bandwidth.
Application Scenarios
LAN network
Video, audio and data service center.
Especially suitable for gigabit Ethernet (IEEE802.3z).
Product Specification
|
Characteristics |
Conditions |
Data |
|
Optical Characteristics |
||
|
Attenuation (dB/km) |
@850nm |
≤ 2.4 |
|
@1300nm |
≤ 0.6 |
|
|
@953nm |
≤ 1.8 |
|
|
Macrobend Loss (dB) |
Radius(mm) |
15 |
|
Number of turns |
2 |
|
|
Max. at 850 nm (dB) |
≤ 0.1 |
|
|
Max. at 1300 nm(dB) |
≤ 0.3 |
|
|
Macrobend Loss (dB) |
Radius(mm) |
7.5 |
|
Number of turns |
2 |
|
|
Max. at 850 nm (dB) |
≤ 0.2 |
|
|
Max. at 1300 nm (dB) |
≤ 0.5 |
|
|
Overfilled Mode Bandwith (OFLBW) (MKz*km) |
@850nm |
≥ 3500 |
|
@953nm |
≥ 1850 |
|
|
@1300nm |
≥ 500 |
|
|
Effective Modal Bandwith (minEMB) (MKz*km) |
@850nm |
≥ 4700 |
|
@953nm |
≥ 2470 |
|
|
Attenuation Uniformity/Point Discontinuities at 850 and 1300 nm(dB) |
dB/km |
≤ 0.10 |
|
Differential Modal Delay (DMD) |
@850nm |
Meet or surpasse IEC 60793-2-10 standard |
|
Numerical Aperture |
- |
0.200±0.015 |
|
Group Index of Refraction(Neff) |
@850nm |
1.482 |
|
@1300nm |
1.477 |
|
|
Geometrical Characteristics |
||
|
Core Diameter (μm) |
- |
50.0±2.5 |
|
Core Non-Circularity(%) |
- |
≤ 5.0 |
|
Cladding Diameter (μm) |
- |
124.6±0.4 |
|
Cladding Non-Circularity(%) |
- |
≤ 0.6 |
|
Core-Clad Concentricity error (μm) |
- |
≤ 1.0 |
|
Coating Diameter-uncolored (μm) |
- |
242±7 |
|
Coating Non-Circularity (%) |
- |
≤ 6.0 |
|
Coating-Cladding Concentricity error (μm) |
- |
≤ 10.0 |
|
Environment Characteristics (@850nm & 1300nm) |
||
|
Attenuation at Temperature Dependence (dB/km) |
-60 to +85°C |
≤ 0.10 |
|
Attenuation at Temperature Humidity Cycling (dB/km) |
-10℃ to +85℃, 98 %RH |
≤ 0.10 |
|
Water Immersion (dB/km) |
23℃, 30 days |
≤ 0.10 |
|
Heat Aging (dB/km) |
85℃, 30 days |
≤ 0.10 |
|
Damp Heat (dB/km) |
85℃ at 85%RH, 30days |
≤ 0.10 |
|
Mechanical Characteristics |
||
|
Proof stress (GPa) |
% |
≥ 1.0 |
|
kpsi |
≥ 100 |
|
|
Coating strip force (N) |
Peak value, N |
≥ 1.3, ≤ 8.9 |
|
Average value, N |
1.5 |
|
|
Dynamic Fatigue Stress Corrosion Parameter (nd) |
Typical value |
20 |
Note:
SWDM supports the distance http://www.swdm.org/msa/.
Support distance of optical cable at 850nm with maximum attenuation of 3.0dB/km, maximum total loss of fusion/connector of 1.8 dB and maximum root mean square spectral width of VCSEL≤ 0.45nm.
Injection conditions for macro bending loss test shall meet IEC61280-4-1 standards.
Partner





Hot Tags: om5, China om5 manufacturers, suppliers