Product Performance
High bandwidth, low attenuation.
Excellent bending resistance.
Designed for 10Gb/s Ethernet using low-cost 850nm VCSELs.
Application Scenarios
MultiCom® Bending resistant OM3-150 Data Center Fiber is widely used in local area networks (LANs), central office areas, data centers, high-performance data storage networks (SANs), etc., providing the highest bandwidth and achieving the lowest integrated system cost.
It is suitable for 10Gb/s network transmission with transmission distances of up to 150m, and is compatible with 50μm data center fiber in traditional networks.
Product Specification
|
Characteristics |
Conditions |
Units |
Specified values |
|
Optical Characteristics (OM4-P/OM4) |
|||
|
Attenuation |
850nm |
dB/km |
≤ 2.4 |
|
1300nm |
dB/km |
≤ 0.6 |
|
|
Full injection bandwidth OFL |
850nm |
MHz·km |
≥ 700 |
|
1300nm |
MHz·km |
≥ 500 |
|
|
Effective mode bandwidth |
850nm |
MHz·km |
≥ 950 |
|
Numerical aperture |
- |
- |
0.200±0.015 |
|
Zero Dispersion Wavelength(λ0) |
- |
nm |
1295-1320 |
|
Effective group refractive index |
850nm |
- |
1.482 |
|
1300nm |
- |
1.477 |
|
|
Attenuation non-uniformity |
- |
dB/km |
≤ 0.10 |
|
Local discontinuities |
- |
dB |
≤ 0.10 |
|
Geometrical Characteristics |
|||
|
Core diameter |
- |
μm |
50.0±2.5 |
|
Core Non-circularity |
- |
% |
≤ 5.0 |
|
Cladding Diameter |
- |
μm |
125±1.0 |
|
Cladding Non-circularity |
- |
% |
≤ 1.0 |
|
Core-Cladding Concentricity Error |
- |
μm |
≤ 1.0 |
|
Coating Diameter |
- |
μm |
242±7 |
|
Coating/Cladding Concentricity Error |
- |
μm |
≤ 10.0 |
|
Environment Characteristics (@850nm &1300nm) |
|||
|
Attenuation at Temperature Dependence (dB/km) |
-60 to +85°C |
dB/km |
≤ 0.10 |
|
Attenuation at Temperature Humidity Cycling (dB/km) |
-10°C to +85°C, 98 %RH |
dB/km |
≤ 0.10 |
|
Damp Heat (dB/km) |
85°C at 85%RH, 30 days |
dB/km |
≤ 0.10 |
|
Water Immersion (dB/km) |
23℃, 30 days |
dB/km |
≤ 0.10 |
|
Heat Aging (dB/km) |
85℃, 30 days |
dB/km |
≤ 0.10 |
|
Mechanical Characteristics |
|||
|
Proof Stress |
- |
% |
1.0 |
|
- |
kpsi |
100 |
|
|
Coating Strip Force |
Peak value |
N |
1.3-8.9 |
|
Average value |
N |
1.4 |
|
|
Dynamic Fatigue Stress Corrosion Parameter (nd) |
Typical value |
- |
20 |
|
Macro-bend Induced Attenuation |
|||
|
Ø15mm×2 |
850nm |
dB |
≤ 0.1 |
|
1300nm |
dB |
≤ 0.3 |
|
|
Ø7.5mm×2 |
850nm |
dB |
≤ 0.2 |
|
1300nm |
dB |
≤ 0.5 |
|
|
Fiber Length |
|||
|
Fiber length per tray |
- |
km |
1.1-17.6 |